Voltage Range DC Load Side VDC | Power Range DC Load Side kW | Current Range DC Load Side A | Order Code | Line Voltage 3L VAC | Line Frequency Hz |
---|---|---|---|---|---|
0 - 52 V | 0 - 10 kW | 0 - 250 A | TC.P.10.52.250 | 360 - 440 V | 48 - 62 Hz |
0 - 16 kW | 0 - 400 A | TC.P.16.52.400 | 360 - 440 V | 48 - 62 Hz | |
0 - 20 kW | 0 - 500 A | TC.P.20.52.500 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 32 kW | 0 - 700 A | TC.P.32.52.700 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 40 kW | 0 - 1000 A | TC.P.40.52.1000 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 64 kW | 0 - 1400 A | TC.P.64.52.1400 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 96 kW | 0 - 2100 A | TC.P.96.52.2100 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 128 kW | 0 - 2800 A | TC.P.128.52.2800 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
160 kW - MW range | ≥ 3500 A | Contact Sales | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 65 V | 0 - 10 kW | 0 - 193 A | TC.P.10.65.193 | 360 - 440 V | 48 - 62 Hz |
0 - 16 kW | 0 - 308 A | TC.P.16.65.308 | 360 - 440 V | 48 - 62 Hz | |
0 - 20 kW | 0 - 385 A | TC.P.20.65.385 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 32 kW | 0 - 600 A | TC.P.32.65.600 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 40 kW | 0 - 770 A | TC.P.40.65.770 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 64 kW | 0 - 1200 A | TC.P.64.65.1200 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 96 kW | 0 - 1800 A | TC.P.96.65.1800 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 128 kW | 0 - 2400 A | TC.P.128.65.2400 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
160 kW - MW range | ≥ 3000 A | Contact Sales | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 100 V | 0 - 10 kW | 0 - 125 A | TC.P.10.100.125 | 360 - 440 V | 48 - 62 Hz |
0 - 16 kW | 0 - 200 A | TC.P.16.100.200 | 360 - 440 V | 48 - 62 Hz | |
0 - 20 kW | 0 - 250 A | TC.P.20.100.250 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 32 kW | 0 - 400 A | TC.P.32.100.400 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 40 kW | 0 - 500 A | TC.P.40.100.500 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 64 kW | 0 - 800 A | TC.P.64.100.800 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 96 kW | 0 - 1200 A | TC.P.96.100.1200 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 128 kW | 0 - 1600 A | TC.P.128.100.1600 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
160 kW - MW range | ≥ 2000 A | Contact Sales | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 130 V | 0 - 10 kW | 0 - 96 A | TC.P.10.130.96 | 360 - 440 V | 48 - 62 Hz |
0 - 16 kW | 0 - 153 A | TC.P.16.130.153 | 360 - 440 V | 48 - 62 Hz | |
0 - 20 kW | 0 - 192 A | TC.P.20.130.192 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 32 kW | 0 - 308 A | TC.P.32.130.308 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 40 kW | 0 - 384 A | TC.P.40.130.384 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 64 kW | 0 - 616 A | TC.P.64.130.616 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 96 kW | 0 - 924 A | TC.P.96.130.924 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 128 kW | 0 - 1232 A | TC.P.128.130.1232 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
160 kW - MW range | ≥ 1540 A | Contact Sales | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 200 V | 0 - 10 kW | 0 - 63 A | TC.P.10.200.63 | 360 - 440 V | 48 - 62 Hz |
0 - 16 kW | 0 - 100 A | TC.P.16.200.100 | 360 - 440 V | 48 - 62 Hz | |
0 - 20 kW | 0 - 125 A | TC.P.20.200.125 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 32 kW | 0 - 200 A | TC.P.32.200.200 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 40 kW | 0 - 250 A | TC.P.40.200.250 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 64 kW | 0 - 400 A | TC.P.64.200.400 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 96 kW | 0 - 600 A | TC.P.96.200.600 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 128 kW | 0 - 800 A | TC.P.128.200.800 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
160 kW - MW range | ≥ 1000 A | Contact Sales | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 400 V | 0 - 10 kW | 0 - 31 A | TC.P.10.400.31 | 360 - 440 V | 48 - 62 Hz |
0 - 16 kW | 0 - 50 A | TC.P.16.400.50 | 360 - 440 V | 48 - 62 Hz | |
0 - 20 kW | 0 - 63 A | TC.P.20.400.63 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 32 kW | 0 - 100 A | TC.P.32.400.100 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 40 kW | 0 - 126 A | TC.P.40.400.126 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 64 kW | 0 - 200 A | TC.P.64.400.200 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 96 kW | 0 - 300 A | TC.P.96.400.300 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 128 kW | 0 - 400 A | TC.P.128.400.400 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
160 kW - MW range | ≥ 500 A | Contact Sales | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 500 V | 0 - 10 kW | 0 - 25 A | TC.P.10.500.25 | 360 - 440 V | 48 - 62 Hz |
0 - 16 kW | 0 - 40 A | TC.P.16.500.40 | 360 - 440 V | 48 - 62 Hz | |
0 - 20 kW | 0 - 50 A | TC.P.20.500.50 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 32 kW | 0 - 80 A | TC.P.32.500.80 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 40 kW | 0 - 100 A | TC.P.40.500.100 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 64 kW | 0 - 160 A | TC.P.64.500.160 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 96 kW | 0 - 240 A | TC.P.96.500.240 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 128 kW | 0 - 320 A | TC.P.128.500.320 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
160 kW - MW range | ≥ 400 A | Contact Sales | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 600 V | 0 - 10 kW | 0 - 20 A | TC.P.10.600.20 | 360 - 440 V | 48 - 62 Hz |
0 - 16 kW | 0 - 32 A | TC.P.16.600.32 | 360 - 440 V | 48 - 62 Hz | |
0 - 20 kW | 0 - 40 A | TC.P.20.600.40 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 32 kW | 0 - 66 A | TC.P.32.600.66 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 40 kW | 0 - 80 A | TC.P.40.600.80 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 64 kW | 0 - 132 A | TC.P.64.600.132 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 96 kW | 0 - 198 A | TC.P.96.600.198 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 128 kW | 0 - 600 A | TC.P.128.600.264 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
160 kW - MW range | ≥ 330 A | Contact Sales | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 800 V | 0 - 10 kW | 0 - 16 A | TC.P.10.800.16 | 360 - 440 V | 48 - 62 Hz |
0 - 16 kW | 0 - 25 A | TC.P.16.800.25 | 360 - 440 V | 48 - 62 Hz | |
0 - 20 kW | 0 - 32 A | TC.P.20.800.32 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 32 kW | 0 - 50 A | TC.P.32.800.50 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 40 kW | 0 - 64 A | TC.P.40.800.64 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 64 kW | 0 - 100 A | TC.P.64.800.100 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 96 kW | 0 - 150 A | TC.P.96.800.150 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 128 kW | 0 - 200 A | TC.P.128.800.200 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
+/- 160 kW - MW range | ≥ 250 A | Contact Sales | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 1000 V | 0 - 10 kW | 0 - 13 A | TC.P.10.1000.13 | 360 - 440 V | 48 - 62 Hz |
0 - 16 kW | 0 - 20 A | TC.P.16.1000.20 | 360 - 440 V | 48 - 62 Hz | |
0 - 20 kW | 0 - 25 A | TC.P.20.1000.25 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 32 kW | 0 - 40 A | TC.P.32.1000.40 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 40 kW | 0 - 50 A | TC.P.40.1000.50 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 64 kW | 0 - 80 A | TC.P.64.1000.80 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 96 kW | 0 - 120 A | TC.P.96.1000.120 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 128 kW | 0 - 40 A | TC.P.128.1000.160 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
160 kW - MW range | ≥ 200 A | Contact Sales | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 1200 V | 0 - 20 kW | 0 - 20 A | TC.P.20.1200.20 | 360 - 440 or 432 - 528 V | 48 - 62 Hz |
0 - 32 kW | 0 - 33 A | TC.P.32.1200.33 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 40 kW | 0 - 40 A | TC.P.40.1200.40 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 64 kW | 0 - 66 A | TC.P.64.1200.66 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 96 kW | 0 - 99 A | TC.P.96.1200.99 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 128 kW | 0 - 132 A | TC.P.128.1200.132 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
160 kW - MW range | ≥ 165 A | Contact Sales | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 1500 V | 0 - 20 kW | 0 - 16 A | TC.P.20.1500.16 | 360 - 440 V | 48 - 62 Hz |
0 - 32 kW | 0 - 25 A | TC.P.32.1500.25 | 360 - 440 V | 48 - 62 Hz | |
0 - 40 kW | 0 - 32 A | TC.P.40.1500.32 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 64 kW | 0 - 50 A | TC.P.64.1500.50 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 96 kW | 0 - 80 A | TC.P.96.1500.80 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
0 - 128 kW | 0 - 100 A | TC.P.128.1500.100 | 360 - 440 or 432 - 528 V | 48 - 62 Hz | |
192 kW - MW range | ≥ 160 A | Contact Sales | 360 - 440 or 432 - 528 V | 48 - 62 Hz |